Ultra-precise N+1 medical chillers, laminar airflow operating theater ventilation, and sterile indoor environmental control engineered for hospitals, MRI suites, and clinical diagnostic laboratories.
Medical MRI / CT Grade
Laminar Airflow & HEPA
Healthcare facilities require 100% uptime, zero thermal drift, and strict biological airborne particle containment. Sustainergic Tech engineers precision medical cooling solutions, custom MRI chillers, surgical suite laminar flow systems, and negative-pressure isolation wards meeting NABH, ASHRAE 170, and HTM 03-01 standards.
N+1 redundant chillers delivering ±0.1°C liquid temperature MRI & CT Scanner Machines.
Positive-pressure HEPA ceiling distribution grids ensuring unidirectional sterile air velocities (0.45 m/s) over surgical tables.
Directional pressure cascading and 100% HEPA exhaust filtration preventing airborne pathogen cross-contamination.
Ultra-reliable 2°C to 8°C cold room refrigeration with automated remote alarms, dual compressors, and battery backup logs.
Dual-circuit N+1 water chillers engineered for MRI Machines and CT scanners, featuring automatic city water bypass valves and non-ferrous glycol piping loops.
Positive-pressure ceiling plenum assemblies delivering ISO Class 5 sterile airflow, MERV 14 pre-filtration, terminal HEPA filters, and active humidity regulation.
Contaminated air containment ventilation with -15 Pa negative pressure cascading, 100% outdoor air change rates, and bag-in/bag-out HEPA exhaust filtration.
Dual compressor walk-in cold rooms equipped with stainless steel interiors, automatic defrost, 24/7 temperature data logging, and GSM alarm notifications.
Dual independent refrigeration circuits and auto-transfer pumps ensure uninterrupted diagnostic scanning and continuous life-support cooling.
Eliminating thermal drift in delicate diagnostic optics, helium compressors, and pharmaceutical blood bank storage units.
Designed strictly to international healthcare infection control standards, delivering 99.97% airborne pathogen filtration efficiency.
Real-time continuous tracking of differential pressures, temperature setpoints, and relative humidity with instant digital SMS alerts.
Calculating medical equipment heat dissipation (kW), chiller capacities, and thermal gains.
Auditing OT air change rates (ACH), isolation pressure differentials, and thermal targets.
Selecting N+1 redundant medical chillers, non-ferrous piping loops, and HEPA units.
Simulating laminar airflow velocity vectors to eliminate turbulent air pockets over surgical tables.
Installing anti-bacterial stainless ductwork, medical piping, and sealed AHU housings.
Executing TAB airflow balancing, hydronic pressure testing, and thermal stress validation.
Conducting ISO airborne particle counts, pressure differential logging, and NABH compliance sign-off.
Hospital diagnostic chillers, MRI/CT precision liquid cooling, and sterile operating theater HVAC executed by Sustainergic Tech.